All our products are rigorously tested for air and water infiltration as well as structural and energy performance. Bdg testing professionals use only the highest quality testing equipment available to complete testing in accordance with written industry standards and testing protocols from either the american architectural manufacturers association aama or american society for testing and materials astm. Residential windows are tested to simulate a variety of conditions your home may be subjected to, like how much air is kept out of your house in a high wind situation, or how much heat is kept out on a sizzling summer day. E547 test method for water penetration of exterior windows, skylights, doors, and curtain walls by cyclic static air pressure difference. We are also a member of aama american architectural manufacturers association. This voluntary specification was developed by representative members of aama as advisory information and published as a public service. Earthwise windows and doors are designed to meet or exceed performance guidelines set by the american architectural manufacturers association aama. Simonton windows and doors are tested to the advanced aama gold label certification program.
Since that time, aama standards have evolved to include windows and doors of various materials and types, as. Air tightness water tightness wind load resistance forced entry resistance durability doors. Stop a moulding used to hold, position or separate window parts. Class l4 therefore achieves the best air tightness 3 m.
A tested, singlesource window wall assembly built to an aama 450certified standard helps simplify project design and management, speeds installation, and reduces callback risk. Evaluating the field performance of windows and curtain. In canada, standards for the performance of windows are established by the canadian standards association csa. Operable windows, which are also more susceptible to air leakage, are not necessary for ventilation in most commercial buildings but are desired by occupants for control. You may feel some air coming into your home around windows, doors, skylights, electrical. New options for specifying structural airwater performance. Another field testing adaptation of a water test is the use of aama 501. What you need to know about nafs in canada september 10, 2014 in this article, the terms nafs and nafs08 refer to aama wdmacsa 101i.
Aama testing and certification residential window council. What you need to know about nafs in canada blog rdh. The astm e 331 standard test method for water penetration of exterior windows, skylights, doors, and curtain walls by uniform static air pressure difference is a testing standard that describes the procedures to determine the water penetration resistance of windows, curtain walls, skylights, and doors when water is applied using a calibrated spray apparatus while simultaneously applying. Any of a variety of compounds used to fill and seal joints or openings in wood, metal, masonry, and other materials, as contrasted to a sealer. Our windows are window wise certified, csa certified and energy star certified. In the united states, the american architectural manufacturers association aama and the national fenestration rating council nfrc are the primary bodies which set standards for the window and curtain wall industry. A key mulling concept to understand is aama 450 certification, a performance certification rating that is typically required in commercial or highend residential projects and used as a standardization method for rating a mulled window wall assembly. Standard practice for determining the acoustical performance. Aama announced a major change to its window and door certification program, saying the maximum life of aama test reports will be extended from six to 10 years.
Aama standards comparison windows, doors and unit skylights. When you look at different brands and talk to different companies, everyone will tell you why their products are the best. The same air and water tight test chamber is utilized, and a. However, it should be noted that aama 502 refers to astm e1105 for the actual field procedure and test appa ratus requirements. Air leakage windows for highperformance commercial buildings. Each window product line must be tested by an independent laboratory and meet minimum performance standards in three areas critical to performance. Windows and doors airtightness test method the standards provide for 4 classes l1, l2, l3, l4, ranked in order of air tightness, based on. Standardspecification for windows, doors, and unit skylights.
Voluntary specification for field testing of windows and sliding glass doors. While the full breadth of gold label requirements would difficult to cover in sum here the aamas official classification document is over 60 pages long, the main things to know are the standards for air leakage, water leakage, and structural strength. Aama releases updated architectural class windows and. Low air infiltration is critical for a passive solar house, where energy loses must be kept to the absolute minimum. A sample of the unit passed required performance tests for resistance to air leakage, water penetration and wind. The use of fixed windows helps to reduce air leakage because these windows are easier to seal and keep tight. Astm e1425 14 standard practice for determining the.
Whats the range of window air leakage values for good. The following is a list of the principal industry standards which are commonly used to establish the field performance criteria for installed windows and curtain walls in north america. Sound insulation of windows can be improved by increasing the mass of the frames and perimeter infill albeit typically with a negative effect on thermal performance, improving the air tightness of the perimeter construction. Standard practice for installation of exterior windows. Astm e 783, standard test method for field measurement of air leakage through installed exterior windows and doors air leakage rate testing. Aama standards comparison windows, doors and unit skylights 6. Ada accessibility for windows frequentlyasked questions. Air leakage windows either pass or fail this test, any window with an infiltration number above 0.
Glass surface temperature, by itself, is not an indication of air infiltration. Aama certified windows have an affixed label located inside the head of the frame. To achieve impactresistant certification, impactresistant windows are subjected to the structural, air infiltration, water, and forced entry tests described aboveas well as to the astms, or american society for testing and materialss, very stringent astm e1996, standard specification for performance of exterior windows, curtain walls, doors and storm shuttersimpacted. Primarily outlines laboratory performance requirements for resistance to water penetration, air leakage. Acoustical products could require a lower air leakage rate than what is required in this standard in order to achieve the desired acoustical performance. In order to be assigned this certification, a window must meet the american architectural manufacturers association s standards for air leakage, water penetration, wind and forced entry resistance, durability, and thermal window performance. To pass this test as detailed in the industry standard aama wdmacsa 101i. The acoustic performance of windows is a function of framing, glass and joinery see the discussion in glazing.
Astm e 783 standard test method for field measurement of air leakage through installed exterior windows and doors. A comprehensive adm offers home builders and architects with a wider array of aama 450certified assemblies to select from. The interaction of the air barrier airtightness and the. Make sure operable windows are located and detailed in. Rd0154a best2 paper mg evaluating the field performance. Depending on the type of building you have, well use the aama 502 or 503. Aama 241003 standard practice for installation of windows. Utilizing a chamber on the interior or exterior of the specimen, the rate of air leakage through the fenestration assemblies is determined at the project. Bdg utilizes professional testing equipment that is calibrated to each specific testing standard for accurate results. E1105, standard test method for field deter installed exterior windows, skylights, doors, and curtain walls by uniform or cyclic static air pressure difference, andor aama 502. Installed exterior windows, skylights, doors, and curtain walls by uniform or cyclic static air pressure difference, andor aama 502. Rd0154a best2 paper mg evaluating the field performance of.
The national building code of canada and most provincial building codes require that windows meet nafs specifications. Standard testing method for determining rate of air leakage through exterior windows, curtain walls, and doors under. E331 test method for water penetration of exterior windows, skylights, doors, and curtain walls by uniform static air pressure difference. The wdma is limited to wood windows and doors, while the aama encompasses a wide range of materials, from wood, aluminum, vinyl, and fiberglass to the newest composites. Designed to help our members excel in a dynamic and fastmoving future, the fenestration and glazing industry alliance, or fgia, is focused on building better industry synergies from glass to framing. There is no shortage of performance standards in the united states and canada for windows, doors and other fenestration components. Astm e 1105 standard test method for field determination of. Aug 24, 2007 according to aama technical director john lewis, the page document titled standard practice for the installation of windows with flanges or mounting fins in wood frame construction specifically addresses new construction of no more than three stories in height utilizing a membranedrainage system. The aama 502 voluntary specification for field testing of newly installed fenestration products refers to the astm e 783 for the air infiltration portion of new construction quality assurance testing. Windows are tested for air infiltration simulating a 25mph wind or a 1. What you need to know about performance standards and testing. E283 e283m19 standard test method for determining rate of air leakage through exterior windows, skylights, curtain walls, and doors under specified pressure differences across the specimen air leakage rate fenestration components doors exterior doors exterior windows windows.
The lower the number the less air infiltration into your home. Standard or warm edge air or gas filled argonkrypton % duration. The american architectural manufacturers association aama recently released an updated document describing the test procedures and specifications architectural class windows and doors aw. Standard test method for exterior windows, curtain walls. You may feel some air coming in around windows, doors, skylights, electrical outlets, walls. Fenestration standards are always evolving due to changes in technology, building codes and rating system performance requirements. An aamaaccredited independent testing agency shall perform.
Aama window standards specifications and ratings, testing. Excerpt editions do not reflect updates that were issued after the initial publication of the standard specification. All enersave windows meet or exceed north american standard requirements for air tightness, windload resistance, water penetration and forcedentry prevention. Aama started evaluating the thermal performance of windows and doors in 1972. During this testing a constant stream of water is sprayed over a 5 foot section of glass and window frame to determine if there is a leak in the window system. Csa certified, window wise, energy star approved windows. Apdoors manufactures supreme quality windows and doors for a wide range of applications in the construction of quality homes, institutional buildings as well as lowrise and highrise projects. Aama gold label certified windows, are the best, they have to pass both aama and nfrc standards.
Nov 11, 2014 aama updates window and door certification program november 11, 2014. This is especially true for windows, because their performance may significantly differ depending on the weather conditions and other factors. Aama standards comparison windows, doors, and unit. Skylights, doors, and curtain walls by uniform static air pressure difference. In order to account for such situation the corresponding aama test method defines an generic air leakage rate which yields a conservative approach. To pass this test as detailed in the industry standard aama wdmacsa. Both the aama and wdma are trade associations representing manufacturers of windows, doors, and skylights. Air infil tration and water penetration through and around windows are two items commonly. This is the test method almost everyone recognizes as the airplane. Air infiltration is the first phase, water penetration is next, and structural is the third part of the test. The gold certification is aamas highest level of testing with windows and doors being tested for thermal performance as well as air, water and structural integrity. A wide variety of aama windows options are available to you, such as fiberglass, nylon, and stainless steel. You can also choose from folding screen aama windows, as well as from sliding doors aama windows, and whether aama windows is aluminum alloy, plastic, or wooden. Why aama 450 is key to successful window wall assembly jlc.
What is the aama gold label for windows and why does it. Window nfrc ratings and airtightness greenbuildingadvisor. Some relevant standards, specifications and codes of practice on materials, design and installation of. Must be air tight enough to get to the negative pressure spray rack calibrated to a certain water pressure need to have adequate water pressure set up and test everything the day before the scheduled testing bsc experts session test set up water leakage testing expert session windows and water leakage testing november 20, 2014. Aama understanding indoor condensation aama resources. The performancebased, materialneutral north american fenestration standard nafs governing windows, doors and skylights, aama wdmacsa 101i.
Aama and igma, two industry leaders, have unified to form an exponentially stronger alliance. To pass this test as detailed in the industry standard aamawdma csa. Residential windows are often flanged windows typically installed in pan flashed and drained opening commercial glazing can be any number of configurations field tests may or may not be completed under face sealed conditions water leakage testing expert session windows and water leakage testing november 20, 2014. Operable window units with low air leakage rates feature. Sep 08, 2016 the american architectural manufacturers association aama recently released an updated document describing the test procedures and specifications architectural class windows and doors aw.
The aama gold label is sort of like a shortcut to identify highperforming, quality products. Following practices outlined by astm and aama allows becs to perform diagnostic testing with water to simulate rainfall or winddriven rain to identify the source of entry and to follow the leak path. Aama 501 2 water intrusion testing leak inspection youtube. Aama is a voluntary organization that establishes material performance standards for the window and door industries. Aama disclaims all liability for the use, application or adaptation of materials published herein. Aama product certification aama certification overview. An inconsistency in the aama 2400, standard practice for installation of windows with a. So lets see what window standards in canada are like and which agencies are accredited to certify them. Fenestration refers to openings in a building, such as windows, doors, skylights, sloped glazing, curtain walls and storefronts, designed to permit the passage of air, light. When applied properly, field testing is a useful way to verify the actual installed performance of fenestration products during construction and prior to occupancy of a building. For my house, i have roughly 250 ft2 or window area, so a. The aama 91016, voluntary life cycle specifications and test methods for aw class architectural windows and doors, was last updated in 2010.
Why aama 450 is key to successful window wall assembly. To test the water tightness of your buildings windows, tsi uses aama 501. Standard test method for water penetration of exterior windows, skylights, doors, and curtain walls by cyclic static air pressure. The first aama voluntary standard for thermal performance was developed specifically to measure the condensation resistance of windows and sliding glass doors. Sovell investigative testing and consulting sitc is a third party independent testing agency that provides testing utilizing both astm international standards and american architects and manufactures association aama specifications. The astm e 331 standard test method for water penetration of exterior windows, skylights, doors, and curtain walls by uniform static air pressure difference is a testing standard that describes the procedures to determine the water penetration resistance of windows, curtain walls, skylights, and doors when water is applied using a calibrated. Field and mockup testing services architectural testing derry court york, pa 174068405. Aama updates window and door certification program graham.